NEA Diagnostics
← Verify another certificate
NEA Diagnostics
Certificate of analysis
2026-HGGGGGGGF

Semax - 10mg

Tested for: IQON

Reported 5/26/2026

PASS
Purity
99.78%
Label claim
10 mg
Measured
10.38 mg
Of label
103.8%
COA #
2026-HGGGGGGGF
Lot number
5344
Accession
HGGGGGGGF
Labeled content
10 mg
Purity
99.78%
Net peptide content
10.38 mg
Appearance
White Lyophilized Powder
Received date
5/20/2026
Reported date
5/26/2026
Mass identificationPurityNet peptide content
Semax99.78%10.38 mg

Identity confirmation

Status
Confirmed
Expected mass
813.9 Da
Observed mass
813.9 Da

Mass spectrometry

Electrospray ionization confirms the target mass.

[M+2H]2+
407.96 m/z
[M+H]+
814.91 m/z

HPLC chromatogram

LC-MS/MS purity, reverse phase HPLC with UV at 214 nm

2.35.56mAUmin
PeakRT (min)Area %
Solvent front2.30.2
Semax main peak5.599.78
Related impurity60.02

Heavy Metal Analysis (ICP-MS)

TestSpecificationResultsStatus
Arsenic (As)NMT 1.5 ppmNot detectedPASS
Cadmium (Cd)NMT 1.5 ppmNot detectedPASS
Chromium (Cr)NMT 5 ppmNot detectedPASS
Mercury (Hg)NMT 1.5 ppmNot detectedPASS
Lead (Pb)NMT 1.0 ppmNot detectedPASS

Sterility Testing (PCR)

TestSpecificationResultsStatus
Sterility (PCR)No GrowthNo GrowthPASS

Endotoxin Testing (USP <85>)

TestSpecificationResultsStatus
Endotoxin (USP <85>)Report ResultNMT 0.05 EU/mLReported

About this result: contamination is reported as a quantitative value. Acceptable limits vary by product type and dose route; no unversioned threshold applies to RUO products. This result is below commonly referenced endotoxin thresholds.

Instrument: Agilent 1260 Infinity II with 6120 single quad MS
Laboratory: NEA Diagnostics, San Diego, CA

This page is the authoritative version of certificate 2026-HGGGGGGGF. Any PDF copy should match it exactly. For research use only.

Searchable via labneadiagnostics.comCOA # 2026-HGGGGGGGF · Issued 5/26/2026