NEA Diagnostics
Certificate of analysis
2026-889TYHFGW
KLOW - 80mg
Tested for: IQON
Reported 6/25/2026
PASS
Purity
99.68%
Label claim
80 mg
Measured
80.67 mg
Of label
100.8%
COA #
2026-889TYHFGW
Lot number
9956
Accession
889TYHFGW
Labeled content
80 mg
Purity
99.68%
Net peptide content
80.67 mg
Appearance
Blue Lyophilized Powder
Received date
6/17/2026
Reported date
6/25/2026
Mass identificationPurityNet peptide content
GHK-Cu / KPV / BPC-157 / Thymosin Beta-499.68%80.67 mg
Identity confirmation
Status
✓ Confirmed
Expected mass
340.8 Da
Observed mass
340.8 Da
Mass spectrometry
Electrospray ionization confirms the target mass.
GHK-Cu [M+H]+
341.81 m/z
KPV [M+H]+
343.41 m/z
BPC-157 [M+H]+
1420.5 m/z
Thymosin Beta-4 [M+H]+
4964.5 m/z
HPLC chromatogram
LC-MS/MS purity, reverse phase HPLC with UV at 214 nm
PeakRT (min)Area %
Solvent front0.30.32
GHK-Cu0.942
KPV1.511.68
BPC-157525
Thymosin Beta-4621
Heavy Metal Analysis (ICP-MS)
TestSpecificationResultsStatus
Arsenic (As)NMT 1.0 ppmNot detectedPASS
Cadmium (Cd)NMT 1.0 ppmNot detectedPASS
Chromium (Cr)NMT 5 ppmNot detectedPASS
Mercury (Hg)NMT 1.5 ppmNot detectedPASS
Lead (Pb)NMT 0.5 ppmNot detectedPASS
Sterility Testing (PCR)
TestSpecificationResultsStatus
Sterility (PCR)No GrowthNo GrowthPASS
Endotoxin Testing (USP <85>)
TestSpecificationResultsStatus
Endotoxin (USP <85>)Report ResultNMT 0.05 EU/mLReported
About this result: contamination is reported as a quantitative value. Acceptable limits vary by product type and dose route; no unversioned threshold applies to RUO products. This result is below commonly referenced endotoxin thresholds.
Instrument: Agilent 1260 Infinity II with 6120 single quad MS
Laboratory: NEA Diagnostics, San Diego, CA
This page is the authoritative version of certificate 2026-889TYHFGW. Any PDF copy should match it exactly. For research use only.
Searchable via labneadiagnostics.comCOA # 2026-889TYHFGW · Issued 6/25/2026